ANSI/VITA 46.11 lets a VPX plug-in module implement system management at one of three tiers. Each tier is a superset of the one below it. The tier sets which IPMI commands the module's IPMC must answer and what the Chassis Manager can expect from it.

Tier-1: the mandatory minimum

A Tier-1 IPMC answers the Chassis Manager's questions. It reports its device ID and FRU address, runs a self test, describes its sensors in a Device SDR repository, returns sensor readings, lets the Chassis Manager read and write its FRU inventory, and supports Set IPMB State so the Chassis Manager can take a failed bus out of use. It does not send messages of its own.

Tier-1 is enough when the Chassis Manager only needs to discover modules, read their inventory and poll their sensors.

Tier-2: events and resets

Tier-2 adds the IPMC's own voice. It sends Platform Event messages to the Chassis Manager when a sensor crosses a threshold, so faults are reported when they happen instead of at the next poll. It also adds Cold Reset and FRU Control Capabilities.

Choose Tier-2 when the system has to react to faults promptly, or when the Chassis Manager requires events.

Tier-3: full management

Tier-3 adds the rest: Warm Reset and FRU Control, FRU activation and policy, payload modes, per-sensor event enables, a System Event Log with its own time, the FRU hash, Mandatory Sensor Numbers, BMC global enables, and IPMB at 400 kHz.

Choose Tier-3 when the Chassis Manager controls payload activation itself, when the system keeps a log of events on each module, or when the system specification calls for it.

Side by side

TierCommands in our IPMCWhat the tier adds
Tier-114Device ID, self test, Device SDR, sensor readings, FRU inventory read and write, Set IPMB State, FRU address information
Tier-218Platform Event messages, event receiver, Cold Reset, FRU Control Capabilities
Tier-336Warm Reset, FRU Control, activation and policy, payload modes, sensor event enables, System Event Log, FRU hash, 400 kHz IPMB

The command counts are those of the IronKernel IPMC. Other implementations count optional commands differently.

How to pick a tier

  • Start from the Chassis Manager. Its documentation, or the system specification, says which tier it expects from plug-in modules.
  • Plan for the next program. A module designed for Tier-1 today may go into a Tier-3 chassis later. Firmware that builds every tier from one source tree turns that into a build switch.
  • Check the hardware. Tier-3 adds 400 kHz IPMB, so check that your I2C ports and bus layout support it.

The IronKernel IPMC builds Tier-1, Tier-2 and Tier-3 from one Rust source tree.